Wastewater testing laboratory in Verona

Self-monitoring of discharges to sewers, surface water or soil: BOD5, COD, nitrogen and pH with ACCREDIA accredited tests.

ACCREDIA no. 00589Google average rating 4.8 out of 5

Why you can trust Biolab 2000

Who has to check discharges, and against which limits

Do you have an authorised discharge and need to carry out self-monitoring? Do you need a test to renew your permit or to check your treatment plant? Wastewater testing lets you verify that your effluent meets the emission limit values of Legislative Decree 152/2006 (D.Lgs. 152/2006), Part III, Annex 5, or those stated in your permit.

The limits vary according to where the discharge goes: Table 3 for discharges to surface water and to sewers, Table 4 for discharges to soil. For discharges to sewers, the regulations and limits of the water service operator also apply. The permit, for example the Single Environmental Authorisation (AUA), states which parameters to check and how often.

Biolab 2000 tests pH, BOD5, COD, ammonium nitrogen, nitrate nitrogen and nitrite nitrogen in wastewater with ACCREDIA accredited tests.

Which water we test

  • Industrial wastewater discharges, for example from food businesses, wineries, dairies and livestock farms.
  • Effluent from on-site treatment plants and small wastewater treatment plants.
  • Discharges of domestic and similar wastewater (Imhoff tanks, constructed wetlands).
  • First-flush stormwater and runoff from yards and paved areas.
  • Influent to the treatment plant, to check its removal efficiency.

Parameters and accreditation

For accredited tests we state the measuring range covered by the accreditation.

Matrix: wastewater

Parameters and accreditation
Parameter Method Accreditation
pH (measuring range 4-10 pH units) APAT CNR IRSA 2060 Man 29 2003 Accredited
BOD5 (measuring range 1-4000 mg/l O2) APHA Standard Methods 5210 D (2019) Accredited
COD (measuring range 30-1000 mg/l O2) ISO 15705:2002 (excluding clause 10.3) Accredited
Ammonium nitrogen (measuring range 3-65 mg/l NH4) UNI EN ISO 23695:2026 Accredited
Nitrate nitrogen (measuring range 2-90 mg/l N-NO3) UNI ISO 23696-2:2023 Accredited
Nitrite nitrogen (measuring range 0.05-1.8 mg/l N-NO2) PRO-30 rev. 00 2025 Accredited
Non-accredited parameters (4)
Parameters and accreditation: non-accredited parameters
Parameter Method Accreditation
Suspended solids — Not accredited
Phosphorus — Not accredited
Oils and fats — Not accredited
Escherichia coli — Not accredited

Need a quote? Fill in the form at the bottom of the page or give us a call.

Reference regulations

  • Legislative Decree No. 152 of 3 April 2006 (D.Lgs. 152/2006), Part III, Annex 5: emission limit values.
    • Table 3: discharges of industrial wastewater to surface water and to sewers.
    • Table 4: discharges to soil.
    • Tables 1 and 2: discharges from urban wastewater treatment plants (Table 2 for sensitive areas).
  • Discharge permit (Article 124 of Legislative Decree 152/2006) or Single Environmental Authorisation (AUA) (Presidential Decree (D.P.R.) No. 59 of 13 March 2013): sets the parameters, limits and frequency of self-monitoring.
  • Water Protection Plan of the Veneto Region (Piano di Tutela delle Acque, Regional Council Resolution D.C.R. no. 107 of 5 November 2009 and subsequent amendments): regional technical rules on discharges.
  • Sewer regulations of the water service operator, for discharges to public sewers.
  • APAT CNR IRSA 1030 Man 29 2003: water sampling methods.

How to take a wastewater sample

  1. Take the sample from the sampling manhole specified in the permit, downstream of any treatment.
  2. As a rule, Annex 5 requires a composite sample taken over 3 hours. Different sampling times, for example a grab sample, are allowed for specific needs, which must be justified in the sampling report.
  3. For the general parameters (pH, BOD5, COD, nitrogen, solids), use clean plastic bottles and fill them completely. Oils, fats and hydrocarbons require a glass bottle; Escherichia coli requires a sterile bottle. We will tell you the number and size of the bottles in the quote.
  4. Record in the sampling report the type of sample (composite or grab), the start and end times and, if you know it, the flow rate.
  5. Keep the sample cool and in the dark (in the fridge or in a cool bag with ice packs) and bring it to the laboratory on the same day, within 24 hours at most.

The 1 litre sterile bottle with sodium thiosulphate, the only container we supply, is used only for the microbiological test (Escherichia coli). You can collect it at the laboratory or buy it at a pharmacy. You provide the other containers yourself. We can carry out the sampling ourselves, for a fee, within about 100 km of the laboratory in Lugagnano di Sona (VR). We accept samples Monday to Friday, 08:30-13:00 and 14:00-18:00. Full details are on the Sample submission page.

Turnaround times

Normally 7-10 working days from receipt of the sample; the exact time is stated in the quote. By definition, BOD5 requires 5 days of incubation. If your self-monitoring has a deadline, tell us straight away: whenever possible, we agree on priority handling.

Frequently asked questions about wastewater testing

Which parameters do I need to test?

Those stated in your discharge permit or AUA. If they are not stated, we start from the parameters typical of your activity, for example pH, suspended solids, BOD5, COD, nitrogen and phosphorus for a food business. Send us the permit with your quote request.

The frequency is set by the discharge permit or the AUA. Legislative Decree 152/2006 does not set a single frequency for all industrial discharges.

Table 3 of Annex 5 sets the limits for discharges to surface water and to sewers, with two separate columns. Table 4 applies to discharges to soil, which are allowed only in specific cases. Where your discharge goes is stated in the permit.

It is a sample made up of several samples taken over 3 hours and mixed together, so it represents the discharge more accurately than a single sample. It is the type of sample to which Annex 5 of Legislative Decree 152/2006 normally refers for checks on industrial wastewater discharges.

The test report shows the results, the methods and which tests are ACCREDIA accredited. If the authority or the operator requires accredited tests for certain parameters, let us know in your request: we will tell you which ones fall within our accreditation.

Request a quote for wastewater testing

Send us your discharge permit or the list of required parameters: we will send you a quote with sampling instructions, or we can arrange the sampling ourselves. Call +39 045 868 0943 or write to biolabvr.laboratorio@gmail.com.

You are requesting: Water · Wastewater

Request a quote
Only to clarify details about your sample.
Number of samples, parameters required, deadlines. Do not enter health data. For water, say if it comes from a well.

What our clients say

Reviews shown in their original language (Italian)

Google ★ 4.8 · 28 reviews
  • Biolab 2000 è un laboratorio altamente competente e accreditato. È un punto di riferimento affidabile per analisi alimentari (HACCP), veterinarie e delle acque, garantendo risultati certificati e tempi di consegna rapidi. Professionale e sicuro.

    Natan Lovato

  • Ottima esperienza per l’analisi dell’acqua. Servizio preciso e puntuale con personale competente e disponibile a chiarire ogni mio dubbio. Consiglio sicuramente Biolab 2000!

    Anna Falsarolo

  • Ottimo servizio! Ho fatto analizzare l'acqua di casa mia e mi sono trovata molto bene. Lo consiglio 😊

    Giorgia Segattini

  • Mi sono rivolto a loro per l'analisi dell'acqua di casa mia. Personale molto competente e cortese, ho ricevuto i risultati nei tempi indicati.

    Luca Dimaggio

  • Ottima esperienza. Ho trovato un laboratorio ben organizzato, con un elevato livello di competenza tecnica e un approccio rigoroso nella gestione delle analisi e dei campioni. Personale disponibile e sempre pronto a fornire spiegazioni chiare. Consigliato.

    Enrico Varotto

  • Personale professionale sempre disponibile dell'accettazione dei campioni alla comunicazione degli esiti di laboratorio.

    Luc Scapini

  • Laboratorio affidabile e professionale, personale puntuale e organizzato. Servizio preciso e tempi rispettati!

    Grazia Allegri

  • Laboratorio molto competente, affidabile, veloce negli esiti analitici.

    Laura Storti

  • Esperienza molto positiva. Personale gentile, disponibile e professionale.

    Francesca Brentegani

  • Analisi effettuate con puntualità e professionalità. Lo consiglio

    Sara Rigatelli

  • Servizio eccellente, personale gentile e professionale. Tempi rapidi e grande attenzione al cliente. Assolutamente consigliato!

    Mattia Corso

  • Ci siamo rivolti a Biolab 2000 per delle analisi sugli alimenti e siamo rimasti molto soddisfatti. Abbiamo trovato professionalità, competenza e grande disponibilità. Servizio, preciso, puntuale e affidabile. Consigliato!

    Gabriella

  • Laboratorio fantastico e personale top!

    Gaia Dell'Aversana

  • Utilizzo Biolab 2000 per le analisi su matrici alimentari in stabilimenti riconosciuti e ho trovato il servizio affidabile, puntuale e estremamente collaborativo

    Paolo Zonzini

Call Request a quote