Request a quoteGet a quote

Food microbiology testing

Salmonella, Listeria, E. coli and total viable count as accredited tests, for self-monitoring and the criteria of Regulation (EC) 2073/2005.

ACCREDIA no. 00589Google average rating 4.8 out of 5

Why you can trust Biolab 2000

What they check and when you need them

Microbiological testing checks that a food does not contain pathogenic bacteria such as Salmonella and Listeria monocytogenes, and that hygiene indicator organisms (E. coli, Enterobacteriaceae, total viable count) stay within limits. Regulation (EC) No 2073/2005 requires food business operators to verify the microbiological criteria for their products as part of HACCP self-monitoring. Testing is also used to validate a new recipe or a new process, to meet a customer’s request and to find the cause of an anomaly before the product reaches the market.

We test food for human consumption and animal feed, with accredited tests for the main parameters.

Matrices tested

  • Fresh meat, minced meat, meat preparations and meat products
  • Fishery products, fish and molluscs, including frozen
  • Delicatessen, ready meals and ready-to-eat foods
  • Ice cream and pastry products
  • Fruit, vegetables and herbs
  • Eggs, flours, raw materials and semi-finished products
  • Animal feed

Parameters and accreditation

Accredited tests are marked "Accredited"; the official list is in the ACCREDIA database.

Parameters and accreditation
Parameter Matrix Method Accreditation
Salmonella spp. (detection) Foods, feed UNI EN ISO 6579-1:2020 Accredited
Listeria monocytogenes and Listeria spp. (detection) Foods, feed UNI EN ISO 11290-1:2017 Accredited
β-glucuronidase-positive E. coli (enumeration) Foods, feed ISO 16649-2:2001 Accredited
Enterobacteriaceae (enumeration) Foods, feed UNI EN ISO 21528-2:2017/EC 1:2018 Accredited
Coliforms (enumeration) Foods, feed ISO 4832:2006 Accredited
Aerobic colony count at 30 °C (total viable count) Foods, feed UNI EN ISO 4833-1:2022 Accredited
Coagulase-positive staphylococci (S. aureus and other species) Foods, feed UNI EN ISO 6888-1:2023 Accredited
Yeasts and moulds (enumeration) Foods and feed with aw ≤ 0.95 ISO 21527-2:2008 Accredited

Detection tells you whether the microorganism is present or absent in a defined quantity of product (usually 25 g). Enumeration tells you how many microorganisms there are per gram (cfu/g).

Need a quote? Fill in the form at the bottom of the page or give us a call.

Listeria in ready-to-eat foods: the criterion applicable from 1 July 2026

If you produce ready-to-eat foods able to support the growth of Listeria monocytogenes, Regulation (EC) No 2073/2005 requires you to ensure that the criteria are met throughout the shelf life and, where necessary, to verify this with specific studies (Article 3 and Annex II). From 1 July 2026 the criterion amended by Commission Regulation (EU) 2024/2895 applies (Annex I, row 1.2): unless you have demonstrated to the competent authority that Listeria monocytogenes will not exceed 100 cfu/g until the end of the shelf life, the product must be not detected in 25 g even once it is on the market, throughout its shelf life, and not only when it leaves the establishment.

Reference regulations

  • Regulation (EC) No 2073/2005 on microbiological criteria for foodstuffs, as amended, including by Commission Regulation (EU) 2024/2895 on Listeria monocytogenes (applicable from 1 July 2026). Annex I distinguishes food safety criteria (e.g. Salmonella, Listeria) from process hygiene criteria (e.g. E. coli, Enterobacteriaceae, aerobic colony count at 30 °C, coagulase-positive staphylococci).
  • Regulation (EC) No 852/2004 on the hygiene of foodstuffs: self-monitoring based on the HACCP principles (Article 5).
  • Regulation (EC) No 853/2004 laying down specific hygiene rules for food of animal origin.
  • Regulation (EC) No 178/2002: unsafe food (Article 14), withdrawal and recall of products (Article 19).
  • UNI EN ISO 7218 and the UNI EN ISO 6887 series: general requirements for microbiological examinations and preparation of test samples.

Sampling and sample submission

  • Bring the food in its original, intact packaging; if it is loose, put it in a sterile bag or container using clean, disinfected utensils.
  • Quantity: for many checks you need 5 packs from the same batch.
  • Chilled and perishable foods: transport at +2/+8 °C in a cool bag with ice packs; testing must start within 24 hours (highly perishable products, for example molluscs) or 36 hours (perishable products) of sampling: deliver on the same day.
  • Frozen foods: they must still be frozen on arrival. Do not freeze a fresh product.
  • State the batch, expiry date, storage temperature and the tests required.

Full details are on the Sample submission page. If you would rather we took the sample, see On-site inspections and sampling.

Turnaround times

Usually 7-10 working days from receipt of the sample; the exact time is stated in the quote. Detecting a pathogen requires more enrichment and confirmation steps than an enumeration, so turnaround depends on the parameters chosen. For urgent requests call us: where possible we agree priority handling.

Frequently asked questions

What microbiological tests does a restaurant need?

It depends on what you prepare and on what your HACCP plan requires. For delicatessen and ready meals the usual checks are total viable count, E. coli, Enterobacteriaceae, coagulase-positive staphylococci and, for ready-to-eat products, Listeria monocytogenes and Salmonella. Alongside food testing, use surface swabs.

The tests listed in the table are accredited, with that method and on that matrix: Salmonella, Listeria, β-glucuronidase-positive E. coli, Enterobacteriaceae, coliforms, aerobic colony count at 30 °C, coagulase-positive staphylococci, yeasts and moulds in foods and feed with aw ≤ 0.95. Accredited tests are identified in the test report.

The report gives the measured value. If there is a legal limit for that product, for example in Regulation (EC) No 2073/2005, you can compare it directly. For parameters without a legal limit, the reference values in your self-monitoring plan or in your customer’s specification are used.

If the product does not meet a food safety criterion, Regulation 2073/2005 (Article 7) and Regulation 178/2002 (Article 19) require you to withdraw or recall the product or batch and to inform the competent authority. Then you need to find the cause: raw materials, process, surfaces.

For many checks under Regulation 2073/2005 you need 5 packs from the same batch.

Yes: all the accredited microbiological tests in the table also apply to feed, with the same methods; for yeasts and moulds, as for foods, only with aw ≤ 0.95. See also Feed testing.

Request a quote for microbiological testing

Tell us the product, the batch and the parameters you need, or tell us what you need the test for: we will suggest the right tests. Or call us on +39 045 868 0943.

You are requesting: Food · Food microbiology testing

Request a quote
Only to clarify details about your sample.
Number of samples, parameters required, deadlines. Do not enter health data.

What our clients say

Reviews shown in their original language (Italian)

Google ★ 4.8 · 28 reviews
  • Biolab 2000 è un laboratorio altamente competente e accreditato. È un punto di riferimento affidabile per analisi alimentari (HACCP), veterinarie e delle acque, garantendo risultati certificati e tempi di consegna rapidi. Professionale e sicuro.

    Natan Lovato

  • Ci siamo rivolti a Biolab 2000 per delle analisi sugli alimenti e siamo rimasti molto soddisfatti. Abbiamo trovato professionalità, competenza e grande disponibilità. Servizio, preciso, puntuale e affidabile. Consigliato!

    Gabriella

  • Utilizzo Biolab 2000 per le analisi su matrici alimentari in stabilimenti riconosciuti e ho trovato il servizio affidabile, puntuale e estremamente collaborativo

    Paolo Zonzini

  • Ottima esperienza. Ho trovato un laboratorio ben organizzato, con un elevato livello di competenza tecnica e un approccio rigoroso nella gestione delle analisi e dei campioni. Personale disponibile e sempre pronto a fornire spiegazioni chiare. Consigliato.

    Enrico Varotto

  • Personale professionale sempre disponibile dell'accettazione dei campioni alla comunicazione degli esiti di laboratorio.

    Luc Scapini

  • Laboratorio affidabile e professionale, personale puntuale e organizzato. Servizio preciso e tempi rispettati!

    Grazia Allegri

  • Laboratorio molto competente, affidabile, veloce negli esiti analitici.

    Laura Storti

  • Esperienza molto positiva. Personale gentile, disponibile e professionale.

    Francesca Brentegani

  • Analisi effettuate con puntualità e professionalità. Lo consiglio

    Sara Rigatelli

  • Servizio eccellente, personale gentile e professionale. Tempi rapidi e grande attenzione al cliente. Assolutamente consigliato!

    Mattia Corso

  • Ottima esperienza per l’analisi dell’acqua. Servizio preciso e puntuale con personale competente e disponibile a chiarire ogni mio dubbio. Consiglio sicuramente Biolab 2000!

    Anna Falsarolo

  • Laboratorio fantastico e personale top!

    Gaia Dell'Aversana

  • Ottimo servizio! Ho fatto analizzare l'acqua di casa mia e mi sono trovata molto bene. Lo consiglio 😊

    Giorgia Segattini

  • Mi sono rivolto a loro per l'analisi dell'acqua di casa mia. Personale molto competente e cortese, ho ricevuto i risultati nei tempi indicati.

    Luca Dimaggio

Call Request a quote